GE OEC 9800 C-Arm
- Fully Refurbished
- Fourth Generation OEC C-Arm System
- GE OEC C-Arms Are The Industry Standard Which All Other Systems Are Compared To
- Rotating Anode X-Ray Tube
- 1K x 1K Image Resolution
- Digital CCD Camera
- 9″ and 12″ Image Intensifier Options
- Standard “C” and Super “C” Options
Brochures:
GE OEC 9800 Brochure | GE OEC 9800 Specifications Brochure
Categories: C-Arms By Brand, C-Arms By Size, Full Size, GE / OEC
Tags: 9800, C-Arm, Fluoroscopy, GE, Mobile, OEC, Plus, Refurbished
Description:
Since the 1970s OEC C-Arm systems have been the industry standard and the GE OEC 9800 is no different.
The GE OEC 9800 C-Arm system builds off the popular GE OEC 9600, and improves it by offering an increased resolution (1,000 x 1,000 pixel resolution vs the 9600’s 512 x 512), touch-screen controls, additional configurations (PMCare, Neuro-Vascular, and Cardiac packages), additional physical options such as MD Models (motorized movements), and increased storage options (additional image storage on disk as well as built-in DICOM). The c-arm was manufactured from 2000 to 2005 with the 9800 Plus models being manufactured from 2003-2005.
The Equipped MD Difference.
Equipped MD offers all configurations of the GE OEC 9800 and refurbishes everything in-house using our 25 years of c-arm refurbishing experience. All GE OEC systems go through our in-depth process which includes:
- 300 Point Inspection Of Internal Parts
- Replacement Of Wear Items
- New Main Battery Packs
- New CMOS & GIB Board Level Batteries
- New Brake Pads
- New Paint – Complete
- Factory Calibration
- Includes FDA Report Of Assembly (Form 2579)
- Standard 30 Day Warranty, Optional 6 Months & 1 Year Options
- Shipping Available To All 50 States
Generator:
- 60kHz high frequency
- 15kWpower
- Up to 120kVp
- Continuous high-level fluoro (HLF) up to 20mA
- Digital spot up to 75mA
Digital cine pulse:
- -15 pulses per second, 60 Hz
- -12 pulses per second, 50 Hz
- -Up to 150mA
- -10ms pulse width
X-Ray Tube:
- Rotating anode x-ray tube
- 0.3 and 0.6 nominal focal spots
- Anode heat capacity: 300,000 HU
- Anode cooling rate: 85,000 HU/min
- Housing heat capacity: 1,600,000 HU
- 9″ (23cm) Standard C-Arm housing cooling rate 15,000 HU/min
- 9″ (23cm) Super C-Arm and 12″ (31cm) Standard C-Arm housing cooling rate 22,500 HU/min
Digital Image Rotation:
- Digitally adjusts image display
- Image update
- -Image rotation
- -Image reversal (side-to-side)
- -Image invert (top-to-bottom)
- Image positioning without additional exposure
PreView Collimator:
- On-screen collimator position indication
- PreView iris collimator
- PreView Tungsten rotatable double leaf collimator
- Adjusts collimators without x-ray exposure
Fluoro Mode:
- kVp range: 40-120
- mA range:
- -0.2-10 normal mode
- -0.2-20 HLF (high level fluoro)
Pulsed Fluoro Mode:
- kVp range: 40-120
- mA range: 0.2 -10
- Pulse rate: 1, 2, 3, 8
- Pulse width: 25 or 50 ms
Digital Spot Mode:
- kVp Range: 40-120
- mA range: up to 75
- Automatic exposure termination and automatic image save
Radiographic Mode:
- mA range: up to 75
- mAs range: up to 300
- Computer controlled exposure time
- Optional film casette holder
- -10×12″ for 9″ II
- -14×14 for 12″ II
Video Imaging System:
9″ Image Intensifier:
- Tri-mode 9″/6″/4.5″ (23cm/15cm/11cm) image intensifier
- Minimum central resolution (at the monitor):
- -9″ (23cm): 2.1 lp/mm
- -6″ (12cm): 2.9 lp/mm
- -4.5″ (11cm): 3.4 lp/mm
- DQE: 65% (typical)
12″ Image Intensifier:
- Tri-mode 12″/9″/6″ (31cm/23cm/15cm) image intensifier
- Minimum central resolution (at the monitor):
- -12″ (31cm): 1.5 lp/mm
- -9″ (23cm): 2.1 lp/mm
- -6″ (12cm): 2.9 lp/mm
- DQE: 65% (typical)
Autotrak Automatic Brightness Stabilization (ABS):
Automatically seeks the subject anatomy anywhere within the imaging field and selects the optimum imaging technique
Automatically adjust to anatomical size and location
Provides uniform image quality throughout entire image
Simplifies operation
Video Camera:
- High resolution 1k x 1k CCD camera
- Full frame capture
- Motorized rotation
- On-screen orientation indicator (real-time feedback without fluoro)
- Left-right image reversal
- Top-bottom image invert
Hardcopy Options:
- Integrated film/paper printer
- -No film developing required
- -8×10″ (20.3cm x 25.5 cm) laser quality film/paper
- -Multi-format, 1,2, 4 on 1
- -Multi-copy capability
- Thermal printers
Video Display (Upgraded Retrofit Kit):
- 32″ LED Lit LCD Display With Dual Screen Capabilities
- Anti-glare, progressive full frame scan monitor
- Touch screen system control
- 2 Mega Pixel high-resolution output
- Ambient room-light compensation
GE OEC 9800 C-Arm
Fully Refurbished
Fourth Generation OEC C-Arm System
GE OEC C-Arms Are The Industry Standard Which All Other Systems Are C